Thick-film Carbon Dual-Electrode
Carbon-based screen-printed dual-electrodes with a four-electrodes approach. Ideal to work with microvolume, showing an excellent intra- and inter-electrode precision. Useful for developing low-cost, multiplexed chemical sensors and biosensors. Different accessories available.
Thick-film Carbon Dual-Electrode
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE1/2: C / RE: Ag / AE: C
WE size: 1,0x2.5 mm (2,3 mm2 )
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
ED-D2PE-C10 (50 units/box)
Mediated Thick-film Carbon/CoPc Electrode
Mediated screen-printed electrodes featuring a carbon working electrode infused with Cobalt (II) Phthalocyanine. This mediator makes the electrodes suitable for using with oxidase enzymes where hydrogen peroxide (H2O2) is generated and detected at low potentials. Thick-film sensors fabricated on a flexible and high-resist PET substrate with a classical three-electrodes approach. This technology enables the detection of numerous analytes in conjunction with specific oxidase type enzymes. Different accessories available.
Mediated Thick-film Carbon/CoPc Electrode
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-CoPc / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
ED-S1PE-C20/CoPc (50 units/box)
Mediated Thick-film Carbon/PB Electrode
Mediated screen-printed electrodes featuring a carbon working electrode infused with Prussian Blue. This mediator makes the electrodes specific to hydrogen peroxide (H2O2) detection at low potentials (near 0 V). Thick-film sensors fabricated on a flexible and high-resist PET substrate with a classical three-electrodes approach. This technology enables the detection of numerous analytes in conjunction with specific oxidase type enzymes. Different accessories available.
Mediated Thick-film Carbon/PB Electrode
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-PB / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
ED-S1PE-C20/PB (50 units/box)
Mediated Thick-film Carbon/FeCN Electrode
Mediated screen-printed electrodes featuring a carbon working electrode infused with Potassium Ferrocyanide. This mediator enhances the suitability of the electrodes for using with Horseradish Peroxidase (HRP), enabling efficient detection of hydrogen peroxide (H2O2). Thick-film sensors fabricated on a flexible and high-resist PET substrate with a classical three-electrodes approach. This technology enables the detection of numerous analytes in conjunction with peroxidase and other oxidase type enzymes. Different accessories available.
Mediated Thick-film Carbon/FeCN Electrode
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-FeCN / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
ED-S1PE-C20/FeCN (50 units/box)
16 Products. View all
We ship the products under strict security measures, ensuring their protection...
More information